RF Fractional Scar Removal Machine Anti-Age Fractional RF Microneedle Machine Stretch Marks and Scar Removal

Customization: Available
Theory: RF (Radio Frequency)
Application: Salon

Product Description

Basic Info.
Model NO.
M37-2
Portable
Non Portable
Voltage
AC 100V-240V
Output Power
30-200W
Fuse
10A
Treatment Area
Face, Neck, Body
Machine Weight
5kg
Package Size
39*35*54cm/9kg
Handle
1
Instant Temperature
400 Degree
Production Capacity
5000
Ti-xel Machine for Skin Care scar removal and stretch mark removal etc.
RF Fractional Scar Removal Machine Anti-Age Fractional RF Microneedle Machine Stretch Marks and Scar Removal
Product Description
1. What is Ti-xel?

Ti-xel is a thermal fractional skin rejuvenation system powered by Thermo-Mechanical Action (TMA) technology. Ti-xel employs a hot titanium tip which transfers direct heat to the upper dermis. The proprietary tip is constructed of biocompatible temperature resistant titanium alloy. The tip consists of an array of tiny pyramids which are heated to a temperature of 400°C. The apex of the pyramids transfers energy to skin by very brief controlled contact. Treatment is nearly painless. Analgesic creams are typically not required. Healing is fast and down time short. Based on Thermo-Mechanical Ablation (TMA) technology, the Ti-xel impacts the targeted tissue almost identically to fractional CO2 and erbium lasers, however with low pain, safely with no side effects. Healing is fast and down time short. Ti-xel offers a new dimension in compactness, ergonomic design, and operating comfort to its users who will also benefit from significant cost savings in equipment, maintenance, operating costs and in floor space.

2. Advantages
  • The ultra-fine peeling and safe instrument does not irritate the skin, only natural heat conduction.
  • Fast treatment (15-30 minutes): superior heat conduction, heat conduction of 0.1 milliseconds; amazing penetration depth, depth up to 500 microns.
  • Safely treating with extremely low pain, a comprehensive breakthrough, multi-effect treatment to regulate skin condition.
  • There is no need for anesthesia, simple operation and post care.
  • After treatment, the part is different from the traditional laser, no skin breaking, no burning, no bleeding.
  • Compared with the traditional laser scar removal, it does not need irradiation, uses natural heat energy to transfer, less damage and shorter repair period.
  • The instrument is light, portable, and highly flexible.
RF Fractional Scar Removal Machine Treatment Area
RF Fractional Scar Removal Machine Working Tip
3. Titanium therapeutic head
  • High temperature resistance: It can be used for a long time under the temperature of 600 ºC or even higher, and can conduct heat conduction efficiently and stably.
  • Corrosion resistance: Even if worn, it will heal by itself or regenerate.
  • High strength: Titanium has extremely high strength. It can reduce weight and is very durable.
  • Non-toxic and non-magnetic: Non-toxic and compatible with human tissues and blood.
  • No cleaning required: Non-sticky, automatic dry heat sterilization system.
4. Parameter settings
Therapeutic Site ms μm
Forehead / jaw (shallow area) 5-6ms 200-400μm
Cheek / neck 8-12ms 200-600μm
Body 10-18ms 700-1000μm
Detailed Images
Detailed Product View 1
Detailed Product View 2
Detailed Product View 3
Detailed Product View 4
Before and After Treatment
Before and After Treatment Results
Client Feedback
Treatment Feedback Graph
Manufacturing Facility & Facility Showcase

Started from Year 2009, our facility is one of the most professional manufacturers making various kinds of top beauty and slimming equipment, including:

  • Cavitation RF vacuum machines
  • IPL (Intense Pulsed Light) Hair Removal machines
  • RF (Radio Frequency) Skin Rejuvenation Systems
  • No needle mesotherapy machines
  • LED Skin Rejuvenation beauty machines
  • Micro needle derma pen / derma rollers
  • Diamond and crystal microdermabrasion Systems
  • Cryolipolysis cavitation rf machines
  • Teeth whitening machines
  • SPA capsules
  • Professional OEM/ODM services

We insist on the ideal of "technology innovation, professional manufacturer, and sincere service" and the operating principle "customer priority, and mutual benefits". Quality is the soul of our production standards.

Manufacturing Line
Quality Inspection
Our Service
  • Warranty: We offer a comprehensive one-year warranty.
  • 24 Hours Online Service: Prompt assistance whenever required.
  • OEM/ODM Service: Custom logo printing matching customers' unique brand demands.
  • Support Documentation: Detailed user manuals and instructional videos provided post-purchase.
  • Bulk Pricing: Highly competitive price structures for high-volume orders.
Frequently Asked Questions

How many treatments do I need?

Generally, 3 to 5 treatments are recommended to achieve the expected clinical outcome.

How long does a single treatment take?

The topical anesthetic cream requires 20 to 30 minutes to take effect prior to treatment. The treatment session itself takes 20 to 30 minutes, including complete post-treatment care. Therefore, each session requires approximately 1 hour. All treatment tips are fully disposable post-treatment to ensure hygiene.

How long is the recovery time after the treatment?

Expect mild swelling and slight redness for the first 1 to 3 days. The overall downtime involved is significantly reduced because this treatment targets the deeper dermal layers while leaving the outer epidermis virtually intact.

What are the advantages of the Titanium Head?

The biocompatible titanium tip is extremely temperature-resistant, highly durable, and completely non-toxic. It conducts heat exceptionally stably at 400°C and features an automatic dry heat sterilization system, requiring no manual cleaning.

Is the treatment painful and does it require anesthesia?

No, treatment is nearly painless and extremely safe with no side effects. Analgesic creams or general anesthesia are typically not required, allowing simple operations and easy post-care.

How does this technology compare to traditional laser scar removal?

Unlike traditional lasers, this system uses natural, direct thermo-mechanical heat conduction rather than radiation. This results in minimal skin damage, no skin breaking, no burning, no bleeding, and a significantly shorter healing period.

Treatment Areas and FAQ Info Graphic

Related Products